Cody, looking up the numbers (after I posted the response above) you are correct! I just never updated my original post, but I will update and post flow numbers here!
Here is what I saved
KA24DE Head flow numbers
Quote:
Intake:
Valve Lift / CFM
.100" = 120.2
.200" = 195.4
.300" = 253.3
.400" = 279.2
.500" = 283.6
Exhaust:
.100" = 110.5
.200" = 165.3
.300" = 187.7
.400" = 197.4
.500" = 200.6
|
SR20DET
Quote:
intake test at 28in H2O, temp 88deg F
SR20DET
Lift CFM
.060 43.4
.080 60.7
.120 92.9
.180 134.5
.260 175.6
.340 192..3
.440 201.8
.460 202.3
.480 203.5
.500 203.6
exhaust test at 28in H2O, temp 95deg F
Lift CFM
.100 41.1
.140 75.0
.200 98.2
.240 106.5
.280 110.2
.360 113.0
.440 114.3
.480 114.7
.500 114.9
|