smoke comming from a ground wire? Check your voltages:

1) - to + battery terminals while cranking (less than 10V = bad bad something)
2) - bat terminal to starter + terminal while cranking (less than 10v = bad something)
3) + bat terminal to starter + terminal while cranking (more than .5v = bad cable)
4) engine block to - bat terminal while cranking (more than .5V = bad ground)