Thread: TPS Help
View Single Post
Old 02-06-2013, 07:17 PM   #7
2.5T_/<ouki
Zilvia FREAK!
 
2.5T_/<ouki's Avatar
 
Join Date: Oct 2011
Location: SoCal
Posts: 1,150
Trader Rating: (13)
2.5T_/<ouki is just really nice2.5T_/<ouki is just really nice2.5T_/<ouki is just really nice2.5T_/<ouki is just really nice2.5T_/<ouki is just really nice2.5T_/<ouki is just really nice2.5T_/<ouki is just really nice2.5T_/<ouki is just really nice2.5T_/<ouki is just really nice
Quote:
Originally Posted by Iconoclast View Post
When probing the wires.. they all read 4.95v.. shouldn't one read 5, one .5 and the other, nothing?

Ohm testing: new sensor 1.6k open 5k closed
old sensor 5k open 13.3k closed .. the old one is garbage, right?
You are not going to ohm test it..

Black probe on the MM goes into the Ground via the TPS (black wire).

Now, your TPS should read .4-.5v idle and 4.0 - 4.5v WOT. This is with the TPS connected.

Here:
https://www.youtube.com/watch?v=rKK7QdochkI
2.5T_/<ouki is offline   Reply With Quote